Kiosk Error Screens

The basic error screens on a Redbox have different color backgrounds, indicating the problem at a basic level. Credits to @mordanthanus in the Discord for posting this info.

Below are pictures of the error screens. Credits to @.jandajanda for these pics also posted in the Discord

Kiosk Error Codes

These error codes show on screen in maintenance mode. Credits to @mordanthanus in the Discord for posting this info.

= 0073CDRR =

- MS will always dispatch these due to an EMV error.

= 0099CDRR =

- Indication that the EMV has failed or been tampered with. Plan on bringing one with you. Alert Irruptions are not field repairable.

= 0072CDRR =

- EMV disconnected. If a remote reboot doesn’t fix it, a visit is needed.

= 0096KRNL =

- Kiosk Engine has put up the maintenance view directly

= 005PMXA =

- Put away max attempts exceeded

= 0128VNDR =

- Vend door error

= INITSYNC =

- Initial Sync is currently running

= 001ISTG =

- ItemStuckInGripper returned by HAL during vend or return

= 002OBDT =

- ObstructionDetected returned by HAL during vend or return

= 003CCFA =

- CameraCaptureFailure returned by HAL during vend or return

= 004MACH =

- MachineError returned by HAL during vend

= 006MVFA =

- MoveFailure returned by HAL during vend

= 0032RSVB =

- Reservation pickup could not find the reserved barcodes in stock

= RPCSSM =

- Session closed to show maintenance during a return

= 0048PPBE =

- Preposition Picker Basket Empty during checkout

= 0064SCBE =

- Shopping Cart Basket Empty during vend

= HALSVCNR =

- HAL Services are not running.

= HALSTS-043 =

- One of the following conditions are met: 

1) The Door is open and the two door sensors (switches) are not pressed in.  

2) Gripper Obstructed (Fingers not retracted, Track not Closed, Sensors 1 or 6 on) 

3) Motion Controller Communication error (unable to communicate to Arcus/Proteus) 

4) Door sensors aren’t properly closed, or someone opened the kiosk while the picker or drum was moving.

= SOFTFILE_01 =

- The kiosk engine reports a database access error and places the kiosk into maintenance mode.* Try restarting the kiosk engine; if the error persists, send it to Level 2 for possible software support escalation.

= SOFTFILE_02 =

- The kiosk engine reports a database access error and places the kiosk into maintenance mode.* SOFTFILE_02 errors should be sent directly to Software support by Level 1

= SOFTFILE_03 =

- The kiosk engine reports a database access error and places the kiosk into maintenance mode. Send to level 2 for possible software support escalation.

= 0073CDRR =

- MS will always dispatch these due to an EMV error.

= 0099CDRR =

- Indication that the EMV has failed or been tampered with. Plan on bringing on with you. Alert Irruptions are not field repairable.

= CCF 

- Camera Capture Failure.

Powering On a Redbox Kiosk Computer After a BIOS Reset

Redbox kiosk computers are configured to automatically power on when connected to a power source (autoboot). However, if the BIOS is reset—whether from a manual reset or due to a CMOS battery failure—this autoboot setting will revert to its default state and become disabled. After this, the computer will require a manual power-on each time until the autoboot setting is re-enabled in the BIOS.

Locating the Power Button on Premio Computers

On Premio computers, the power button is discreet and may not be immediately visible. It is located on the back of the unit, near the I/O panel. Look for a small button close to the I/O LEDs (typically used to indicate network or drive activity). Pressing this button will power on the computer, allowing access to the BIOS to re-enable the autoboot setting if needed.

Note: Once the autoboot on power setting is re-enabled in the BIOS, the computer should resume automatic boot-up on power connection, as originally configured.

 

Kiosk not showing titles despite having titles in the database

If the start screen is blank (no carousel with titles), and the Rental screen is not showing any titles except for replacement cases despite all title data being intact, you will need to change the kiosk date and time into the past. The reason for this issue is currently unknown, but it may be caused from clearing the CMOS.